| Our Products |
| Digital Home UPS – PQ Series |
PQ Series is an advanced Digital Home UPS range based on latest technology. Continuing with the tradition of launching products with innovative features, PEPTELLER has launched PQ Series Home UPS in 850 VA model. PEPTELLER PQ Series Home UPS introduces 1st time in India the following technologies:
- Battery meter technology
- Power Booster technology
- LCD display in digital Home UPS
|
| . |
 |
| |
 |
|
PQ Series Features: |
|
|
PQ Series is an advanced Digital
Home UPS range based on latest
technology. Continuing with the tradition of launching products with innovative
features, PEPTELLER has launched PQ Series Home UPS in 850 VA model. PEPTELLER PQ Series Home UPS introduces 1st
time in India
the following technologies: |
|
v
Battery meter
technology:
PQ
Series has the technology to sense battery health and displays it on the LCD
screen. With this the customers are aware about the state of their battery and
can change their battery well in time. Battery
meter technology also displays the charge remaining in battery (just like
mobile phones) for efficient power management. Battery
health is displayed in the first line while battery charge status is displayed
in the second line on LCD display. Battery
health keeps changing depending upon the remaining life of the battery. At the
end of usable life of battery, Replace battery indication is displayed.
|





|
|
Legend: |
|
 |
- Filled blocks indicate amount of charge in battery |
|
 |
- Arrows indicate battery charging process |
|
 |
- Empty blocks indicate unusable capacity of
battery |
|
|
Power Booster technology
In
many situations customers want to run heavy loads for small duration of time on
low capacity Home UPS systems.
Typical examples are Tullu pump, toaster, mixer, etc. Other Home UPS products simply go into overload mode and
shutdown. But, PQ Series solves this problem by running 115% load for duration
of 10 minutes. This means that customers can now run heavy loads without spending
extra money on bigger capacity Home UPS
system.
|
 |
|
LCD display in digital Home
UPS
PEPTELLER
is the only branded company in India
which provides Digital Home UPS
systems with LCD display. LCD display indicated the load running during backup
mode. By switching off unnecessary load, the backup time can be doubled. This
is called load management and is not possible with LED display products.
|

 |
|
Best charging on Low Mains Voltage
PQ
Series solves the problem of many customers who complain that batteries do not
get charged properly during the summer season when Mains Voltage is very low.
And this is a common phenomenon in many Indian states. PQ Series provides 7A of
charging current even at 130V Mains Voltage. Now PEPTELLER customers can
continue living comfortably in any season.
|
 |
|
|
|
|
| |
 |
|
| |
| |
Options |
| Appliance |
Typical load |
| Computer |
150W |
| Television |
100W |
| Fans |
70W |
| Tube Light |
40W |
| CFL light |
15W |
|
| A |
B |
C |
| 1 |
|
|
| |
1 |
|
| 1 |
1 |
2 |
| 1 |
2 |
3 |
| 6 |
7 |
8 |
|
|
|
| |
| |
Special microcontroller for Inva tubular batteries (High final charging voltage) to enable them to be fully charged. |
|
| |
| Notes: |
| 1.The above calculations are indicative values only. Actual load may vary depending on the make and model of the appliance used. |
| 2. When PC is running, it is not recommended to turn on the TV as it may reboot the PC. |
| |
| Back-up time and charging time estimates: |
| With High Charging setting is selected, the estimates of the back-up time and charging time are as under: |
| |
| |
| Back-up time at half load |
| Back-up time at full load |
| Charging time |
| |
|
| 100 AH |
120 AH |
150 AH |
| 4 Hours |
4 hours 50 minutes |
6 hours |
| 2 Hours |
2 hours 25 minutes |
3 hours |
| 12 hours |
14 hours 20 minutes |
18 hours |
| |
|
|
|
| 180 AH |
| 7 Hours 10 minutes |
| 3 hours 35 minutes |
| 21 hours |
| |
|
|
|
| |
| Note: |
| 1.The above table shows that if you are planning to run the Home UPS at full load, then this model is suitable for Power Cut Duration (PCD) of total 3 and a half hours in a day (24 hours). For half load, they can support PCD of about 7 hours / day. |
| 2. Note that these durations are indicative figures for fresh batteries. |
| 3. Pepteller recommends Inva-tubular (special batteries for inverter / UPS application supporting deep discharge) batteries from a reputed make like Exide, Tata Green etc. |
| |
|
I |
Mains
operating Voltage |
|
| |
i) Wide voltage range |
100V to 280V ± 5V |
| |
ii) Narrow voltage range |
170V to 265V ± 5V |
|
II |
Battery Parameters |
|
| |
a.
Battery Voltage |
12 V |
| |
b.
Battery Capacity |
120-180AH |
| |
c.
Full Charge Voltage |
14.5
+ 0.1 V DC |
| |
d.
Low battery cut-off voltage |
10.2
+ 0.2V DC |
| |
e.
Battery Charge voltage |
|
| |
i. Wide Voltage range
ii. Narrow Voltage range
- H_UPS switch OFF
- H_UPS switch ON |
115 - 280 + 5 Volts DC
115 - 280 + 5 Volts DC
170 - 265 + 5 Volts DC |
| |
f. Battery Charging current
i. Normal Charging mode
ii. Fast Charging mode |
115 - 280 + 5 Volts DC
8.0 + 0.5 A DC
12.0 + 0.5 A DC |
|
III |
Backup mode frequency |
50.0
Hz + 2% |
|
IV |
Fuse Rating
a. Charging fuse
b. Internal fuse |
10 A
40 A Auto Fuse X 3 |
| |
|
|
| |
| Note: |
In our continual endeavor for improvement, we reserve the right to change specifications at any time without notice. |
| |
| |
| |