Fast acting protection circuit to prevent damage to the Home UPS in case of output getting overloaded or accidentally short. Pepteller Home UPS is protected against overload and short circuit with fast acting electronic protection. On overload, it retries 5 times to start the output generation with beep sound to allow you to reduce load on the home UPS. |
| |
No damage to the Home UPS even in case of ‘dead short’at the output. |
|
|
| |
| |
Options |
| Appliance |
Typical load |
| Tube Light |
40W |
| Fans |
70W |
| CFL light |
15W |
| Television |
100W |
| Computer |
150W |
|
|
|
|
| |
| |
Special microcontroller for Inva tubular batteries (High final charging voltage) to enable them to be fully charged. |
|
| |
| Notes: |
| 1.The above calculations are indicative values only. Actual load may vary depending on the make and model of the appliance used. |
| 2. When PC is running, it is not recommended to turn on the TV as it may reboot the PC. |
| |
| Back-up time and charging time estimates: |
| With High Charging setting is selected, the estimates of the back-up time and charging time are as under: |
| |
|
| |
| Note: |
| 1.The above table shows that if you are planning to run the Home UPS at full load, then this model is suitable for Power Cut Duration (PCD) of total 3 and a half hours in a day (24 hours). For half load, they can support PCD of about 7 hours / day. |
| 2. Note that these durations are indicative figures for fresh batteries. |
| 3. Pepteller recommends Inva-tubular (special batteries for inverter / UPS application supporting deep discharge) batteries from a reputed make like Exide, Tata Green etc. |
| |
|
I |
Mains operating Voltage |
|
| |
i) Wide voltage range |
100V to 280V ± 5V |
| |
ii) Narrow voltage range |
170V to 265V ± 5V |
|
II |
Battery Parameters |
|
| |
a. Battery Voltage |
12 V |
| |
b. Battery Capacity |
40AH-65AH |
| |
c. Full Charge Voltage |
14.5 + 0.1 V DC |
| |
d. Low battery cut-off voltage |
10.2 + 0.2V DC |
| |
e. Battery Charging current (Mains Supply) |
5A + 0.5 Hz |
|
III |
Backup mode frequency |
50.0 Hz + 2% |
|
IV |
Fuse Rating
a. AC fuse |
10 A |
|
V |
Charge over time (Narrow Mode) |
< 15 ms |
| |
PQ 250S (With Solar
Charger) |
|
I |
Solar Charger |
Maximum Power Point Tracking (MPPT) Based |
|
II |
Recommended Solar Panel |
75 Wp |
| |
*Specifications may change in the process of
products improvement |
| |
|
|
| |
| Note: |
In our continual endeavor for improvement, we reserve the right to change specifications at any time without notice. |
| |
| |